Inspecting and Assembling a 37° Flared Tube End

37 Degree Flared Fitting

Incorrect installation and assembly of hydraulic fittings are major causes for leakage in hydraulic systems. By preventing leakage in your hydraulic systems, you can avoid unnecessary costs such as: The high price of hydraulic oil Maintenance costs Energy loss System inefficiencies Environmental concerns 37° flared fittings seal systems by employing the use of metal-to-metal contact […]

Continue reading

Why You Cannot use Camlock Fittings for Steam Applications

Why You Cannot Use Camlock Fittings for Steam Applications
While camlock fittings make for quick and easy connections for low-pressure fluid transfer, these types of connections are dangerous for both operators and machines when used in steam applications. As a result, camlock fittings should never be used for steam applications. Liquid dynamics and the ability to vary boiling points by increasing temperature and pressure within [...] Continue reading